Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips

Product Details
Disposable: Disposable
Certification: CE, ISO
Material: Rubber / Plastic
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
  • Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
  • Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
  • Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
  • Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
  • Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
Find Similar Products

Basic Info.

Model NO.
20-0010/20-0200/21-1000/20-1250/20-1251
Volume
10µl, 200µl, 1000µl, 5/10ml
Color
Blue/Natural/Yellow
Sterile
Yes/No
Package
1,000 Tips/Pack, 10 Packs/Case
Autoclavable
Yes
Total
10000 /Case
Specification
CE, FDA, ISO
Trademark
Biologix
Origin
China
HS Code
3926909090
Production Capacity
500 Cases/Month

Product Description

Laboratory Disposable PP 10µl, 200µl, 1000µl, 5ml, and 10ml Bulk/Racked Pipette Tips

Feature:
· Made of polypropylene, autoclavable
· Available in 10µl, 200µl, 1000µl, 5ml, and 10ml sizes, ---suitable for standard manual and electronic pipettes
· 10µl and 200µl tips are graduated, 200µl tips have a ---beveled point design that reduces sample retention Extended 1000µl tips facilitate pipetting from deep or ---narrow containers
· RNase & DNase free, non-pyrogenic
· Available in racked package (sterile) and bulk package --(non-sterile)


Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips
Ordering Information
Cat # Volume Color Sterile Unit Total
20-0010 10μl Natural No 1,000/Bag, 2 Bags /Pack, 5 Packs/Case 10000 Tips/Case
21-0010 10μl Natural Yes 96 /Rack,10 Racks/Pack,10 Packs/Case 9600 Tips/Case
20-0200 200μl Yellow No 1,000/Bag/Pack,10 Packs/Case 10000 Tips/Case
21-0200 200μl Yellow Yes 96 /Rack,10 Racks/Pack,10 Packs/Case 9600 Tips/Case
20-1000 1000μl Blue No 1,000 /Bag/Pack,10 Packs/Case 10000 Tips/Case
21-1000 1000μl Blue Yes 100 /Rack,6 Racks/Pack,10 Packs/Case 6000 Tips/Case
20-1250 1000μl Extended Natural No 1,000 /Bag/Pack,10 Packs/Case 10000 Tips/Case
21-1250 1000μl Extended Natural Yes 96/Rack,6 Racks/Pack,10 Packs/Case 5760 Tips/Case
20-1251 1000ul Extra-Long Blue No 1,000/Bag/Pack,10 Packs/Case 10000 Tips/Case
21-5000ES 5ml Natural Yes 24/Rack,30 Racks/Case 720 Tips/Case
20-5000ES 5ml Natural No 100 /Bag,20 Bags/Case 2000 Tips/Case
21-1100ES 10ml Natural Yes 24 /Rack,40 Racks/Case 960 Tips/Case
20-1100ES 10ml Natural No 100/Bag,10 Bags/Case 1000 Tips/Case
21-5000TS 5ml Natura Yes 40 /Rack,40 Racks/Case 1600 Tips/Case
20-5000TS 5ml Natural No 100/Bag,20 Bags/Case 2000 Tips/Case
21-1100TS 10ml Natural Yes 24/Rack,40 Racks/Case 960 Tips/Case
20-1100TS 10ml Natural No 100 /Bag,10 Bags/Case 1000 Tips/Case


Laboratory Disposable PP 10/200/1000µ L, 5ml, and 10ml Bulk/Racked Pipette Tips1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?

We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier