0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Reactant State: Liquid
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C
  • 0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C
  • 0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C
  • 0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C
Find Similar Products

Basic Info.

Material
Rubber / Plastic
Color
Clear Pink Green Blue Yellow
Vocume
0.2ml
Working Temperature
Stable From -20ºC to 100ºC
Withstands Maximum Centrifugal Force
6000g
Cap Type
Flat Domed
Transport Package
125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
Specification
0.2ml 8-Strip
Trademark
Biologix
Origin
China

Product Description

0.2ml 8 Strip flat cap dome cap pcr tubes DNase, RNase, and endotoxin free
0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C
0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C
 
0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C
0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C

Features:

--Made of prime virgin polypropylene

--Ultra thin-wall offers high degree of transparency, easy for observation and heat conduction

--Domed caps ensure efficient heat transfer, while flat caps are ideal for Real-Time PCR(qPCR);

--unique design prevents opening during cycling and incubation

--DNase, RNase, and endotoxin free

--Re-sealable plastic bags packed in individual boxes-keeping them contamination-free and easily stored

--Temperature range: stable from -20ºC to 100ºC
-- Universal fits for the PCR instrument; withstand centrifugation of 6,000 RCF in a fully supported rotor

--CE/FDA/ISO Certificates are all available from Biologix!

0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C

 
Cat# Volume Color Cap Sterile Unit
60-0088 0.2ml Clear Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0188

0.2ml Pink Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0288

0.2ml Green Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0388

0.2ml Blue Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0488

0.2ml Yellow Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0008 0.2ml Clear Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0108 0.2ml Pink Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0208 0.2ml Green Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0308 0.2ml Blue Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0408 0.2ml Yellow Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case


0.2ml 8 Strip Flat Cap Dome Cap PCR Tubes Dnase, Rnase, and Endotoxin Free Stable From -20º C to 100º C

1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?

To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier