Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Material: Plastic
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps
  • Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps
  • Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps
  • Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps
Find Similar Products

Basic Info.

Model NO.
60-
Capacity
0.2ml PCR Tubes
Name
0.2ml PCR Tubes
Made of
PP Cryovial Tubes
Dnase and Rnase Free
Dnase and Rnase Free
Endotoxin Free
Endotoxin Free
Caps
Flat Caps and Domed Caps
Volume
0.2ml
Transport Package
1000 Pieces/Bag/Pack, 10 Packs/Case
Specification
0.2ml PCR tubes
Trademark
Biologix
Origin
China
Production Capacity
1000000 Cases/Month

Product Description

Laboratory Plastic PP PCR Single Tubes Ultra thin-wall 0.2ml DNase, RNase, and endotoxin free Flat and Domed Caps

 

Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed CapsLaboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps

Features:

1. Made of prime virgin polypropylene

2. Ultra thin-wall offers high degree of transparency, easy for observation and heat conduction

3. Domed caps ensure efficient heat transfer, while flat caps are ideal for Real-Time PCR(qPCR);

Unique design prevents opening during cycling and incubation

4. DNase, RNase, and endotoxin free

5. Temperature range: stable from -20ºC to 100ºC

6. Universal fits for the PCR instrument; Withstand centrifugation of 6,000 RCF in a fully supported rotor

* Assorted colors for PCR tubes should be ordered separatelly
 

Ordering Information

Cat # Volume Color Cap Sterile Unit
60-0082 0.2ml Clear Flat-top NO 1,000/Pack, 10 Bags/case
60-0002 0.2ml Clear Dome-shaped NO 1,000/Pack, 10 Bags/case
 
 Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps
Laboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed CapsLaboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed CapsLaboratory Plastic PP PCR Single Tubes Ultra Thin-Wall 0.2ml Dnase, Rnase, and Endotoxin Free Flat and Domed Caps
  1. What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
    What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
    What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

     

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier