Biologix Laboratory Diameter 13mm, 25mm, 50mm With Superior Flow Rates Vent Filters
Feature:
· The filters are basically incorporates a hydrophobic PTFE membrane in a polypropylene housing, provide excellent thermal and chemical compatibility The Vent filters are available in diameter 13mm, 25mm, 50mm, with pore sizes 0.22µm or 0.45µm and different connections.
· Integrity testable
· Robust design and construction allow for multiple autoclave cycles
· Designed to be reusable but also offers the convenience of being disposable
· Available in pre-sterilized or non-sterilized packaging
· PTFE Membrane and polypropylene housing offer broad chemical compatibility
· Optimized PTFE membrane provides superior flow rates in a compact device
· Provides ULPA filtration (>99.999% @ 0.3um)
Applications:
· Sterile Venting of bioreactors, fermentation tanks, media flasks, and carboys
· Sterile gas purge of cell culture vessels or flling vessels In-line sterilization of and particulate removal from air and gases
· Obstruct moisture to protect equipment.
Ordering Information
Cat # |
Material |
Pore Size |
Housing Diameter |
Sterile |
Package |
BV-PTFE5022N |
Hydrophobic PTFE |
0.22μm |
13mm |
Yes |
20 Pcs/Box |
BV-PTFE5045N |
Hydrophobic PTFE |
0.45μm |
13mm |
Yes |
20 Pcs/Box |
BV-PTFE50100N |
Hydrophobic PTFE |
1μm |
13mm |
Yes |
20 Pcs/Box |
BV-PTFE5022S |
Hydrophobic PTFE |
0.22μm |
13mm |
Yes |
20 Pcs/Box |
BV-PTFE5022TS |
Hydrophobic PTFE |
0.22μm |
13mm |
Yes |
20 Pcs/Box |
BV-PTFE5045S |
Hydrophobic PTFE |
0.45μm |
13mm |
Yes |
20 Pcs/Box |
BV-PTFE50100S |
Hydrophobic PTFE |
1μm |
13mm |
Yes |
20 Pcs/Box |
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.