Cryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free Barcode

Product Details
After-sales Service: 5 Years
Warranty: 5 Years
Disposable: Disposable
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Cryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free Barcode
  • Cryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free Barcode
Find Similar Products

Basic Info.

Model NO.
1.5ml
Certification
CE, ISO, FDA
Reactant State
Liquid
Material
PP
Cap Color
Assorted
Writing Area
Yes
Volume
0.5ml
Type
Vials
Sterile
Gamma Sterile
Side Barcode
Yes
Rnase&Dnase Free
Yes
Working Temperature
-196-121
2D Barcode
Yes
Transport Package
25 Sets/Bag, 40 Bags/Case
Specification
External Thread
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3917220000
Production Capacity
200 Cases/Week

Product Description

 1.5ml  external Thread Cryogenic vials with RNase&DNase free disposable sterile
 
Cryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free Barcode
Cryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free Barcode
Cryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free Barcode

Characteristic
 

1. Made of medical grade polypropylene; can be repeatedly frozen and thawed

2. 1.5ml cryogenic vials are available with external screw thread

3. Internal thread vials' caps are with o-rings, which will promote more secure sealing

4.DNase & RNase free, endotoxin free, foreign DNA free

5. With side barcode and digital code by Side laser printing, easy for information storage

6. Working temperature: stable from -196°C to 121°C

7. Suitable for liquid nitrogen freezing


Ordering Information
 
88-9150 1.5 ml vial, white cap, 2D Barcoded, PP, No O-ring, 25 Pieces/Bag, 20 Bags/Pack, 2 Packs/Case, Two free boxes included
88-9151 1.5 ml vial, red cap, 2D Barcoded, PP, No O-ring, 25 Pieces/Bag, 20 Bags/Pack, 2 Packs/Case, Two free boxes included
88-9152 1.5 ml vial, green cap, 2D Barcoded, PP, No O-ring, 25 Pieces/Bag, 20 Bags/Pack, 2 Packs/Case, Two free boxes included
88-9153 1.5 ml vial, blue cap, 2D Barcoded, PP, No O-ring, 25 Pieces/Bag, 20 Bags/Pack, 2 Packs/Case, Two free boxes included
88-9154 1.5 ml vial, yellow cap, 2D Barcoded, PP, No O-ring, 25 Pieces/Bag, 20 Bags/Pack, 2 Packs/Case, Two free boxes included
88-9155 1.5 ml vial, purple cap,  2D Barcoded, PP, No O-ring, 25 Pieces/Bag, 20 Bags/Pack, 2 Packs/Case, Two free boxes included

*Call for information cryogenic vials


Cryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free BarcodeCryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free BarcodeCryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free BarcodeCryogenic Tubes Vials 1.5ml Sterile Rnase&Dnase Free Barcode1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier