5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Material: PP PS
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
  • 5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
  • 5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
  • 5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
  • 5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
  • 5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
Find Similar Products

Basic Info.

Model NO.
5ml 8ml
Capacity
5ml 8ml
Type
Test Tubes
Color
Clear
Sterile
No
Caps Color
Red Blue
Description
Tube
Name
Test Tubes
Volume
5ml 8ml
Unit
500/Bag, 4bags/Case
Transport Package
500 Sets/Pack, 4 Packs/Case
Specification
12x75mm, 13x100mm
Trademark
Biologix
Origin
Changzhou Jiangsu China
HS Code
39172900
Production Capacity
200cases/ Month

Product Description

PP PS Disposable laboratory Clear Plastic Conical Bottom Cylindrical Test Tubes Non-sterile  5ml and 8ml
  
5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
 
5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile

Characteristic
 

1.Tubes: made of medical grade polystyrene or polypropylene

2.Caps: made of medical grade polyethylene

3.Tubes are available in two sizes: 12 × 75mm and 13 × 100mm

4.Caps are available in two colors: red or blue

    Ordering Information
     
    Cat # Description Size(mm) Material Color Volume Sterile Unit
    12-1275 Tube 12x75 PS Clear 5ml NO 500 Sets/Pack, 4 Packs/Case
    12-2275 Tube 12x75 PP Clear 5ml NO 500 Sets/Pack, 4 Packs/Case
    12-1300 Tube 13x100 PS Clear 8ml NO 250 Sets/Pack, 8 Packs/Case
    12-1299 Cap 12x13.5 PE Blue - NO 1,000 Sets/Pack, 2 Packs/Case
    12-1399 Cap 13x17.5 PE Red - NO 1,000 Sets/Pack, 2 Packs/Case
    5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile5ml 8ml 12*75mm 13*100mm Disposable PP/PS Test Tubes Non-Sterile
    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier