Sterile Syringe Filters 0.22/0.45um Laboratory Consumables

Product Details
After-sales Service: 5 Years
Warranty: 5 Years
Disposable: Disposable
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
  • Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
  • Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
  • Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
  • Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
  • Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
Find Similar Products

Basic Info.

Model NO.
0.22/0.45um
Certification
CE, ISO, FDA
Material
PP Material
Capacity
None
Color
Blue, Green
Steril
Yes
Package
Individual Package
Membrane
Ca, Pes, Nylon, Pvde
Pore Size
0.22um, 0.45um
Diameter
13mm,25mm,30mm,33mm
Transport Package
Individual Package, 100/Pack, 4 Packs/Case
Specification
CE, FDA, ISO9001
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
Production Capacity
200 Cases/Week

Packaging & Delivery

Package Size
5.00cm * 3.00cm * 1.00cm
Package Gross Weight
1.000kg

Product Description

Features:

* Single Use and Gamma Ray pre-sterilized.  

* Sterile graded 0.2um membrane: LRV>7 for Brevundimonas diminuta, ATCC19146.  

* Non-pyrogenic, low extractables and surfactant-free ensures purity of filtrate.  

* Extreme-low Protein Binding <1.5% (PES).   

* Excellent Thoughput, for faster filtration and more process volume.

Applications:

1. Sterile filtration and clarification of biological fluids.

2. Tissue culture media preparation.

3. Protein and enzyme filtration.

4. Hybridization buffers.

5. Other aqueous solution.
 

Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
Sterile Syringe Filters 0.22/0.45um Laboratory Consumables
Ordering Information
 
CAT#   DECRIPTION  TO REPLACE Pack Size
08-PES1322R

Membrane: PES, pore size: 0.22μm, diameter:13mm. 

Female luer lock + male luer slip. Extreme-low protein 

binding. Individually packed.

Millipore SLGV013SL

Whatman 6780-1302/6791-1302

Pall 4602

100 Pcs/Pack, 8 Packs/Case, 

Case of 800

08-PES2522R

Membrane: PES, pore size: 0.22μm, diameter:25mm. 

Female luer lock + male luer slip. Extreme-low protein 

binding. Individually packed.

Millipore SLMP025SS/SLMP025SS

Whatman 6780-2502/6780-2512/

9913-2502

Pall 4612/4902/4907/4520

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

08-PES3022R

Membrane: PES, pore size: 0.22μm, diameter:30mm. 

Female luer lock + male luer slip. Extreme-low protein 

binding. Individually packed.

Millipore SLMP025SS/SLMP025SS

Whatman 6780-2502/6780-2512

Pall 4612/4902

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

08-PES3322S

Membrane: PES, pore size: 0.22μm, diameter:33mm. 

Double luer lock. Extreme-low protein binding.  Individually packed.

Sartorius16532----GUK

Sartorius16532------K

Sartorius16532----------Q

Sartorius 16534---------K

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

08-PES3345S

Membrane: PES, pore size: 0.45μm, diameter:33mm. 

Double luer lock. Extreme-low protein binding. Individually packed.

Sartorius16537-----K 

Sartorius16537-----Q

Sartorius 16555----K

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

08-PES3322M

Membrane: PES, pore size: 0.22μm, diameter:33mm. 

Female luer lock + male luer slip. High pressure resistance. 

Individually packed.

Millipore SLGP033RB/SLGP033RK/ SLGP033

RS/SLGV033RS/ SLGV033RB/SLGV033RK

Sartorius 16541----K/16541----Q

Pall 4652

Whatman1046-2200/1046-2205

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

08-PES3345M

Membrane: PES, pore size: 0.45μm, diameter:33mm. 

Female luer lock + male luer slip. High pressure resistance. 

Individually packed.

Millipore SLHP033RB/SLHP033RS/ SLHV033

RS/ SLHV033RB/ SLHV033RK

Sartorius16533----K/16533----Q

Pall 4654/4406

Whatman 1046-2100

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

08-CA3022R

Membrane: CA, pore size: 0.22μm, diameter:30mm. 

Female luer lock + male luer slip. High biocompatibility. 

Individually packed.

Sartorius 17597----K

Whatman 1046-2200

Whatman 1046-2205

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

08-CA3045R

Membrane: CA, pore size: 0.45μm, diameter:30mm. 

Female luer lock + male luer slip. High biocompatibility. 

Individually packed.

Whatman 1046-2100

100 Pcs/Pack, 4 Packs/Case, 

Case of 400

Sterile Syringe Filters 0.22/0.45um Laboratory ConsumablesSterile Syringe Filters 0.22/0.45um Laboratory ConsumablesSterile Syringe Filters 0.22/0.45um Laboratory ConsumablesSterile Syringe Filters 0.22/0.45um Laboratory Consumables
  1. What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
    What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
    What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
     

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier