8-Channel Decapper Laboratory Automation SBS Standard
8-Channel Decapper
Product Introduction:
By using decapper, the opening of screw cap becomes more convenient. The head is arranged according to SBS standard to achieve that 8 caps in an individual line are opened/closed together. Torque limiting structure of decapper ensures caps sealing completely, but also avoids the situation of damaging sealing ring because of excessive torsion. The decapper is able to open/close Cryogenic Vials' caps in 3 seconds.
Features of Products:
Open or close 8 vials' caps in 3 seconds.
Avoid touching samples or reagents. Reduce the risks of biochemical reagents and biological samples.
It is the lightest among all handheld decappers. Alleviate fatigue caused by long-term use.
CKS-4008 fits for Bologix internal vials: 89-4233, 89-4253, 89-4283, 89-4213. CKS-5008 fits for Biologix external vials: 89-504X, 89-508X, 89-514X
Cat# | Lithium battery capacity | Continual operation | Standby time | Decapping time | External dimension(L*W*H) | Fit for |
CKS-4008 | 5500MA | 8h | 30 days | 3s | 95mm*46mm*255mm | Internal thread tube |
CKS-5008 | 5500MA | 8h | 30 days | 3s | 95mm*46mm*255mm | External thread tube |
What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.