Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials

Product Details
After-sales Service: 5 Years
Warranty: 5 Years
Disposable: Disposable
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials
  • Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials
  • Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials
  • Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials
  • Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials
  • Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials
Find Similar Products

Basic Info.

Model NO.
88-510X/88-520X/88-550X
Certification
CE, ISO, FDA
Reactant State
Solid
Material
Rubber / Plastic
Volume
1.0/2.0/5.0ml
Cap Type
Concave Cap/Domed Cap
Color
Sky Blue/Lime Green/Biologix Blue/Lavender Purple
Bottom Barcode
Yes
Side Code
Yes
Sterile
Yes
Unit
48 /Bag, 10 Bags/Pack, 2 Packs/Case
Transport Package
960/Case
Specification
1.0/2.0/5.0ml vials
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Product Description

Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread SBS Format Cryogenic Vials 2D Code Cryovials

Feature:
SBS Format Cryogenic Vial-External (48-well)
Vials: Made of medical grade polypropylene, autoclavable, 2-color injection molding technique Four codes on one vial: Bottom: Laser etched 2D code and human-readable codes; Side: Laser etched 1D barcode and human-readable codes
Two cap types: concave cap and domed cap
Racks: Side: Laser etched 1D barcode, 2D code, and human-readable codes; Bottom: 2D code. Pre-set alphanumeric marks for sample identification. Can be used with CKS-1301 CryoKING scanner to manager samples
Gamma radiations sterilized; DNase & RNase free, endotoxin free, foreign DNA free
Stable from -196°C to 121°C, can be stored in vapor phase liquid nitrogen
Compatible with Micronic cappers & decappers and sample management system

Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials

Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials

Ordering Information

Cat# Material Volume Cap Type Code Unit Total
89-510X-F PP 1 Concave Bottom & side code 10 Sets/Pack, 2 Packs/Case 960 Vials+20 Racks
89-510X-R PP 1 Domed Bottom & side code 10 Sets/Pack, 2 Packs/Case 960 Vials+20 Racks
89-520X-F PP 2 Concave Bottom & side code 10 Sets/Pack, 2 Packs/Case 960 Vials+20 Racks
89-520X-R PP 2 Domed Bottom & side code 10 Sets/Pack, 2 Packs/Case 960 Vials+20 Racks
89-550X-F PP 5 Concave Bottom & side code 10 Sets/Pack, 2 Packs/Case 960 Vials+20 Racks
89-550X-R PP 5 Domed Bottom & side code 10 Sets/Pack, 2 Packs/Case 960 Vials+20 Racks

"X" Stand for a different color: 1-Sky Blue, 2-Lime Green, 3-Biologix Blue, 5-Lavender purple


Laboratory Consumable 48-Well 1.0/2.0/5.0ml External Thread Sbs Format Cryogenic Vials Cryovials 2D Code Freezer Vials1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier