Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks

Product Details
After-sales Service: 5 Years
Warranty: 5 Years
Certification: CE, ISO, FDA
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
  • Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
  • Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
  • Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
  • Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
  • Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
Find Similar Products

Basic Info.

Model NO.
07-8/9
Material
PS
Cap Type
Filter/Plug
Culture Area
25/75/175cm²
Working Volume
7/25/50ml
Total Volume
60/250/650ml
Surface Treatment
Yes
Sterile
Yes
Unit
5 Pieces/Pack, 20 Packs/Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3923300000
Production Capacity
200 Cases/Week

Packaging & Delivery

Package Size
30.00cm * 20.00cm * 18.00cm
Package Gross Weight
8.000kg

Product Description

Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks

Feature:
· Material: polystyrene
· Available flask sizes include surface areas of 25 cm2 , 75 cm2 , 175 cm2 , or 225 cm2
· Plug caps completely isolate the culture from the outside environment
· Filter caps prevent cross-contamination while meeting the requirements for gas exchange
· Short, wide, angled neck design for easy access
· Gamma radiation sterilized
· Non-pyrogenic, non-cytotoxic
· DNase & RNase free, human DNA free
· TC treated
· Suitable for open culture conditions, effectively preventing crosscontamination while meeting the requirements for gas exchange in cell and tissue culture

 

Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks
Ordering Information
Cat # Cap Type Culture Area Working Volume Unit Total
07-8025 Filter Cap 25cm² 7ml 5 /Bag, 40 Bags/Case 200/Case
07-8075 Filter Cap 75cm² 25ml 5 /Bag, 20 Bags/Case 100/Case
07-8175 Filter Cap 175cm² 50ml 5/Bag, 8 Bags/Case 40/Case
07-9025 Plug Cap 25cm² 7ml 5 /Bag, 40 Bags/Case 200/Case
07-9075 Plug Cap 75cm² 25ml 5 /Bag, 20 Bags/Case 100/Case
07-9175 Plug Cap 175cm² 50ml 5/Bag, 8 Bags/Case 40/Case

 

Laboratory Consumables PS Material 25/75/175cm² Lab Supplies Filter/Plug Cap Sterile Cell Culture Flasks1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier