• Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips
  • Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips
  • Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips
  • Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips
  • Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips
  • Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips

Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips

After-sales Service: Yes
Warranty: No
Disposable: Disposable
Certification: CE, ISO, FDA
Power Source: Manual
Material: Rubber / Plastic
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Certifications
CE ISO FDA
Volume
10μl 200μl 100μl Pipet Tips
Sterile
Sterile Pipette Tips
Rack
96 Tips or 100 Tips Per Rack
Dnase & Rnase Free
Dnase & Rnase Free
Non-Pyrogen
Non-Pyrogen
Universal
Universal Pipette Tips
Made in
Made in Cleanroom Pipette Tips
Transport Package
Bulk or Racked Pipette Tips
Specification
10UL 200UL 100UL Pipet Tips
Trademark
Biologix Brand
Origin
Changzhou, Jiangsu
Production Capacity
1000000 Cases/Month

Product Description

Disposable Plastic Racked Universal 10/200/1000/1000μl Extended Dnase and Rnase Free Pipette Tips
 

Feature:

· Autoclavable Different Volumes of Pipette Tips

· Made of polypropylene, autoclavable

· Available in different volumes: 10µl, 200µl, 1000µl, and 1000 µl extended sizes, suitable for standard manual and electronic pipettes

· 10µl and 200µl tips are graduated, 200µl tips have a beveled point design that reduces sample retention

· Extended 1000µl tips facilitate pipetting from deep or narrow containers

· RNase & DNase free, non-pyrogenic

· Available in racked package (sterile) and bulk package (non-sterile)


Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips
Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips

 

Ordering Information

Cat # Volume Color Sterile Unit Total
20-0010 10μl Natural No 1,000 /Bag, 2 Bags /Pack, 5 Packs/Case 10000 /Case
21-0010 10μl Natural YES 96 /Rack, 10 Racks/Pack, 10 Packs/Case 9600 /Case
20-0200 200μl Yellow No 1,000 /Bag/Pack, 10 Packs/Case 10000 /Case
21-0200 200μl Yellow YES 96 /Rack, 10 Racks/Pack, 10 Packs/Case 9600 /Case
20-1000 1000μl Blue No 1,000 /Bag/Pack, 10 Packs/Case 10000 /Case
21-1000 1000μl Blue YES 100 /Rack, 6 Racks/Pack, 10 Packs/Case 6000 /Case
20-1250 1000μl Extended Natural No 1,000 /Bag/Pack, 10 Packs/Case 10000 /Case
21-1250 1000μl Extended Natural YES 96 /Rack, 6 Racks/Pack, 10 Packs/Case 5760 /Case
20-1251 1000μl Extra-Long Blue No 1,000 /Bag/Pack, 10 Packs/Case 10000 /Case

Disposable Plastic Laboratory Racked Universal 10/200/1000/1000 μ L Extended Dnase and Rnase Free Pipette Tips1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP