18cm Cell Scraper 18cm 25cm Made of Polyethylene

Product Details
Color: Blue
Certifications: CE, ISO, FDA
Brand: Biologix
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 18cm Cell Scraper 18cm 25cm Made of Polyethylene
  • 18cm Cell Scraper 18cm 25cm Made of Polyethylene
  • 18cm Cell Scraper 18cm 25cm Made of Polyethylene
  • 18cm Cell Scraper 18cm 25cm Made of Polyethylene
  • 18cm Cell Scraper 18cm 25cm Made of Polyethylene
Find Similar Products

Basic Info.

Model NO.
70-1180
Transport Package
100 Pieces/Case
Specification
CE, ISO, FDA
Trademark
BIOLOGIX
Origin
Changzhou, Jiangsu
HS Code
3926909090
Production Capacity
500 Cases/Month

Product Description

18cm Cell Scraper

Company Interview:
Biologix Group Ltd is founded in USA in the year 2000 and has since been committed to the design and manufacture of high quality, low-priced scientific and biomedical supplies. Throughout its long company history, Biologix has excelled at providing top quality laboratory supplies to distributors at unbeatable prices. Time and time again, after consistently delivering on this promise and expectation, its customers have positioned Biologix among the top manufacturers of laboratory supplies in the world.
Most products manufactured in our U. S. FDA registered facilities are certified sterile, DNase and RNase Free, and non-pyrogenic using the highest quality, international famous medical-grade plastic materials. Some of the world's top branded laboratory supplies, in vitro diagnostic kits, and medical devices are also produced as OEM and / or Private Labeled products.

Guaranteed Quality Professional Design
Exceptional Service Logical Pricing



Features

Cell Scrapers
*Available in two sizes: 18cm and 25cm
*Non-pyrogenic
*Polyethylene
*Pivoting blade makes precise cutting and scraping movements
*Appropriate for a variety of cell culture vessels
*The uniquely designed handle and blade reduce cell damage during the harvesting process
*Pre-sterilized and individually wrapped in peel-open packaging

Cell lifters
*Used with dishes and cell culture clusters for quick removal of cell layers
*Blade Length: 2.0cm; Handle Length: 16cm
*Gamma radiation sterilized and individually wrapped
*Disposable lifters quickly remove cell layers
*The one-piece design and chiseled blade provide improved control while minimizing damage during the cell removal process
*Non-pyrogenic
*Polyethylene
Cat#  
Name
 
 
Handle Length
 
 Sterile Unit
 70-1180  
Cell Scraper
 
 18cm  Yes  
100 Pieces/case
 
 70-1250  
Cell Scraper
 
 25cm Yes  
100 Pieces/case
 
 70-2180  Cell Lifter  18cm  Yes  
100 Pieces/case
 
 18cm Cell Scraper 18cm 25cm Made of Polyethylene
1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
 2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier