Conical Bottom Centrifuge Tubes Gamma Radiation Sterilized, Non-Pyrogenic, Rnase Dnase Free Rack Bulk

Product Details
Certification: CE, ISO, FDA
Material: Rubber / Plastic
Type: Centrifuge Tubes
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Conical Bottom Centrifuge Tubes Gamma Radiation Sterilized, Non-Pyrogenic, Rnase Dnase Free Rack Bulk
  • Conical Bottom Centrifuge Tubes Gamma Radiation Sterilized, Non-Pyrogenic, Rnase Dnase Free Rack Bulk
  • Conical Bottom Centrifuge Tubes Gamma Radiation Sterilized, Non-Pyrogenic, Rnase Dnase Free Rack Bulk
Find Similar Products

Basic Info.

Model NO.
10-915X/10-950X/10-9815/10-9850/10-015X/10-050X
Trademark
Biologix
Origin
China

Product Description

Conical Bottom Centrifuge Tubes Gamma Radiation Sterilized, Non-Pyrogenic, Rnase Dnase Free Rack Bulk

Features

Tubes: made of strong, highly transparent medical grade polypropylene
Flat-top caps: made of medical grade polyethylene
Plug-seal screw on caps: made of medical grade polypropylene
15ml and 50ml conical tubes available;
Large white writing area for easy marking
Double threaded design reduces cross-threading; caps are easily opened and closed
Flat-top caps can be written on
Gamma radiation sterilized, non-pyrogenic, RNase&DNase free
Available in racked package (sterile) or bulk package (sterile & non-sterile) Specifications

Specifications

Working temperature: stable from -20°C to 121°C (except flat-top cap)
15ml and 50ml tubes can withstand centrifugation of 8,400 and 9,400 RCF respectivel
Sealing test: complies with the International Air Transport Association (IATA) Safety Standards

Conical Bottom Centrifuge Tubes Gamma Radiation Sterilized, Non-Pyrogenic, Rnase Dnase Free Rack Bulk
 
 10-0151  15ml, Plug-seal cap, PP, Conical, rack pack, 50 Tubes/rack 500 Tubes/case
 10-0152  15ml, Plug-seal cap, PP, Conical, bulk pack, 50 Tubes/bag 500 Tubes/case
 10-0501  50ml, Plug-seal cap, PP, Conical, rack pack, 25 Tubes/rack 500 Tubes/case
 10-0502  50ml, Plug-seal cap, PP, Conical, bulk pack, 50 Tubes/bag 500 Tubes/case
 10-9151  15ml, Flat-top cap, PP, Conical, rack pack, 50 Tubes/rack 500 Tubes/case
 10-9152  15ml, Flat-top cap, PP, Conical, bulk pack, 50 Tubes/bag 500 Tubes/case
 10-9501  50ml, Flat-top cap, PP, Conical, rack pack, 25 Tubes/rack 500 Tubes/case
 10-9502  50ml, Flat-top cap, PP, Conical, bulk pack, 50 Tubes/bag 500 Tubes/case
 10-9815  15ml, Flat-top cap, PP, Conical,bulk pack 500Tubes/case
 10-9850 50ml, Flat-top cap, PP, Conical,bulk pack 500Tubes/case
 10-0815 15ml, Plug-seal cap, PP, Conical,rack pack 500Tubes/case
 10-0850 50ml, Plug-seal cap, PP, Conical,rack pack 500Tubes/case


Conical Bottom Centrifuge Tubes Gamma Radiation Sterilized, Non-Pyrogenic, Rnase Dnase Free Rack Bulk
    1. What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.  What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.  What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier