• 81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard
  • 81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard
  • 81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard
  • 81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard
  • 81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard
  • 81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard

81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard

Disposable: Disposable
Certification: CE, ISO
Reactant State: Solid
Material: PP Material
Color: Assorted Colors
Transport Package: 20 Pieces/Case
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
90-2281 90-5281 90-2200 90-5200 90-2381 90-2300 9
Specification
CE, FDA, ISO9001
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
4819500000
Production Capacity
200 Cases/Week

Product Description

 

81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard
81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard
81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard

Characteristic

Made of durable cardboard with superior white outer coating

Chemically resistant to alcohols and mild organic solvents

Five assorted colors available: white, yellow, pink, blue, and green

White Premium Cardboard Freezer Boxes have a glossy coating, other colors have a matte coating

Water-resistant coating for improved durability

Superior white 90-1281 & 90-1200 cardboard cryogenic boxes without outer coating are also available

Holds 0.5ml, 1.5ml, 2.0ml, 5ml and 10ml microtubes and 15ml or 50ml Centrifuge Tubes

Working temperature: stable from -196°C to 121°C

Suitable for liquid nitrogen freezing

    Ordering Information
     
    Cat #

    Height

    Well Description Color Unit
    90-2281 2 in 81-well White coating, glossy  coating White 5 /Bag, 20 Bags/Case
    90-5281 2 in 81-well Rainbow outer coating, matte coating Assorted Colors 5 /Bag, 20 Bags/Case
    90-2200 2 in 100-well White coating, matte   coating White 5 /Bag, 20 Bags/Case
    90-5200 2 in 100-well Rainbow outer coating, matte coating Assorted Colors 5 /Bag, 20 Bags/Case
    90-2381 3 in 81-well White coating, glossy  coating White 5 /Bag, 20 Bags/Case
    90-2300 3 in 100-well White coating, glossy  coating White 5 /Bag, 20 Bags/Case
    90-1281 2 in 81-well Superior white without outer coating White 5 /Bag, 20 Bags/Case
    90-1200 2 in 100-well Superior white without outer coating White 5 /Bag, 20 Bags/Case
    90-5016 - 16-well - White

    5 /Bag, 20 Bags/Case

    90-1536 - 36-well - White

    5 /Bag, 20 Bags/Case

     

    81-Well 100-Well Premium Cardboard Freezer Boxes Durable Cardboard


     
    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    Gold Member Since 2021

    Suppliers with verified business licenses

    Manufacturer/Factory
    Type of Ownership
    Limited Company
    Management System Certification
    ISO 9001, GMP