Laboratory Convenient and Efficient Way to Filter Biological Fluids Bell-Shaped Pressure Filtration Units

Disposable: Disposable
Certification: CE, ISO, FDA
Material: Rubber / Plastic
Filtration Unit Diamater: 50mm
GF Prefilter: No GF Prefilter
Pore Size: 0.22μm, 0.45μm, 1.0μm
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
BLF-PES5010SB/BLF-PES5022SB/BLF-PES5045SB
Media
Pes, Ca, PVDF, PTFE
Sterile
Gamma Sterile
Package
10 PCS/Box
Transport Package
Package
Specification
10 Pcs/Box
Trademark
Biologix
Origin
Changzhou, Jiangsu, China

Product Description

Laboratory Convenient and Efficient Way to Filter Biological Fluids Bell-Shaped Pressure Filtration Units

Feature:
· Bell-shaped Pressure Filtration Units offer a convenient and efficient way to filter biological fluids when using a peristaltic pump, syringe or other pressurized source. Wide range of membrane materials and pore sizes are available, offer filtration solution for different types of liquids, up to 5-8 L, for sterile filtration or clarification. PES is ideal for aqueous solutions, especially where low protein binding is required. The filters are available with glass fiber prefilter.
· Sterile graded 0.22μm membrane: LRV>7 for Brevundi-monas diminuta, ATCC19146
· Biosafety qualification USP<87>, USP<88>
· Non-pyrogenic, nuclease-free, low extractable and surfactant-free
· Endotoxin Level<0.25 EU/mL
· Extreme-low protein binding <1.5% (PES)
· Superior flow rates compared to most competitive products
· Excellent thoughput, for faster filtration and more process volume select able detachable filling bell - prevent splashing & contamination

Applications:

· Sterile filtration--0.22μm membranes
· Clarification for liquids Inline filter

Laboratory Convenient and Efficient Way to Filter Biological Fluids Bell-Shaped Pressure Filtration Units
Ordering Information
Cat # Description Package
BLF-PES5010SB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.1μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PES5022SB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.22μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PES5045SB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.45μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PES50100SB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,1μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PES5010SGB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.1μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PES5022SGB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.22μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PES5045SGB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.45μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PES50100SGB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,1μm Pore size,PES media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-CA5022SB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.22μm Pore size,CA media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-CA5045SB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.45μm Pore size,CA media,Gamma Sterile,Inlet: 1/8 in.MNPT
Outlet: Stepped Hose Barb  
10 Pcs/Box
BLF-CA5022SGB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.22μm Pore size,CA media,Gamma Sterile,Inlet: 1/8 in.MNPT
Outlet: Stepped Hose Barb  
10 Pcs/Box
BLF-CA5045SGB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.45μm Pore size,CA media,Gamma Sterile,Inlet: 1/8 in.MNPT
Outlet: Stepped Hose Barb  
10 Pcs/Box
BLF-PVDF5022SLB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.22μm Pore size,PVDF media,Gamma Sterile,Inlet: 1/8 in.MNPT
Outlet: Stepped Hose Barb  
10 Pcs/Box
BLF-PVDF5045SLB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.45μm Pore size,PVDF media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PVDF5022SGLB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.22μm Pore size,PVDF media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PVDF5045SGLB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.45μm Pore size,PVDF media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PTFE5010SLB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.1μm Pore size,PTFE media,Gamma Sterile,Inlet: 1/9 in.MNPT
Outlet: Stepped Hose Barb  
10 Pcs/Box
BLF-PTFE5022SLB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.22μm Pore size,PTFE media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PTFE5045SLB 50mm Bell-shaped Pressure Filtration Unit,no GF Prefilter,0.45μm Pore size,PTFE media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box
BLF-PTFE5010SGLB 50mm Bell-shaped Pressure Filtration Unit,GF Prefilter,0.1μm Pore size,PTFE media,Gamma Sterile,1/4-1/2" (7-13mm) stepped hose barb   10 Pcs/Box

*Please call for more product models


Laboratory Convenient and Efficient Way to Filter Biological Fluids Bell-Shaped Pressure Filtration Units
1.What are the main factors that influence the maximum centrifugal acceleration force? 
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins. 
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower. 
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics? 
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality? 
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP