• Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units
  • Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units
  • Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units
  • Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units
  • Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units
  • Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units

Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units

After-sales Service: 5 Years
Warranty: 5 Years
Pore Size: 0.45um, 0.22μm, 0.45μm
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Order Sample
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units pictures & photos
Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units
US $39 / Box
Min. Order: 1 Box
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
08-PES1322R/08-PES2522R/08-PES3022R/09-PES2250
Membrane Material
Pes/Ca
Diameter
33mm
Individual Packed
Yes
Funnel Volume
500ml
Receiver Volume
500ml
Transport Package
12/Cases
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
1.000kg

Product Description

Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μm Sterile Syringe Filters & Vacuum Units

Feature:
· Sterile Syringe Filters & Vacuum Units
· Syringe filters are suitable for 1ml~150ml liquid or solution, vacuum units are suitable for 150ml~2L liquid or solution
· Single use and gamma ray pre-sterilized
· Sterile graded 0.2um membrane: LRV > 7 for Brevundimonas diminuta, ATCC19146
· Non-pyrogenic, low extractables and surfactant-free ensures purity of filtrate
· Extreme-low protein binding <1.5% (PES)
· Excellent throughput, for faster filtration and more process volume
· The types of membranes are available in PES, CA, NY, PTFE, PVDF

Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45&mu; M Sterile Syringe Filters &amp; Vacuum Units

Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45&mu; M Sterile Syringe Filters &amp; Vacuum Units
Ordering Information
Cat # Description Pore Size(μm) Individual Packed Sterile Unit
08-PES1322R Syringe filters.Membrane:PES, diameter:13mm.Female luer lock
+male luer slip.Extreme-low protein binding. 
0.22 Yes Yes 100/Pack,8 Packs/Case
08-PES2522R Syringe filters.Membrane:PES, diameter:25mm.Female luer lock
+male luer slip.Extreme-low protein binding. 
0.22 Yes Yes 100/Pack,4 Packs/Case
08-PES3022R Syringe filters.Membrane:PES, diameter:30mm.Female luer lock
+male luer slip.Extreme-low protein binding. 
0.22 Yes Yes 100/Pack,4 Packs/Case
08-PES3322S Syringe filters.Membrane:PES, diameter:33mm.Double luer lock.
Extreme-low protein binding. 
0.22 Yes  Yes 100/Pack,4 Packs/Case
08-PES3345S Syringe filters.Membrane:PES, diameter:33mm.Double luer lock
Extreme-low protein binding. 
0.45 Yes Yes 100/Pack,4 Packs/Case
08-PES3322M Syringe filters.Membrane:PES, diameter:33mm.Female luer lock
+male luer slip.High pressure resistance. 
0.22 Yes Yes 100/Pack,4 Packs/Case
08-PES3345M Syringe filters.Membrane:PES, diameter:33mm.Female luer lock
+male luer slip.High pressure resistance. 
0.45 Yes Yes 100/Pack,4 Packs/Case
08-CA3022R Syringe filters.Membrane:CA, diameter:30mm.Female luer lock
+male luer slip.High biocompatibility. 
0.22 Yes Yes 100/Pack,4 Packs/Case
08-CA3045R Syringe filters.Membrane:CA, diameter:30mm.Female luer lock
+male luer slip.High biocompatibility. 
0.45 Yes Yes 100/Pack,4 Packs/Case
09-PES2250 Vacuum filtration unit.Membrane:PES, diameter:90mm,funnel
volume:500ml,receiver volume: 500ml
0.22 No Yes 12/Case
09-PES2250F Vacuum filtration unit-funnel.Membrane:PES, diameter:90mm,
funnel volume: 500ml
0.22 No Yes 24/Case
09-CA2250 Vacuum filtration unit.Membrane:CA, diameter:90mm,funnel
volume:500ml,receiver volume: 500ml
0.22 No Yes 12/Case
09-CA2250F Vacuum filtration unit-funnel.Membrane:CA,
diameter:90mm,funnel volume: 500ml.
0.22 No Yes 24/Case

Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45&mu; M Sterile Syringe Filters &amp; Vacuum Units1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.


2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

From payment to delivery, we protect your trading.
Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units pictures & photos
Laboratory Consumables Liquid Filter Pore Size: 0.22/0.45μ M Sterile Syringe Filters & Vacuum Units
US $39 / Box
Min. Order: 1 Box
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP