50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively

Product Details
Certification: CE, ISO, FDA
Material: Medical Grade Polypropylene
Capacity: 15mL
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
  • 50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
  • 50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
  • 50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
  • 50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
  • 50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
Find Similar Products

Basic Info.

Model NO.
10-0501/10-0502/ 10-9502/10-9501
Sterile
Gamma Sterile
Rnase&Dnase Free
Yes
Bottom
Conical
Cap
Flat Top/ Plug Seal
Disposable
Yes
Autoclavable
Yes
PP
PP Material
Transport Package
500/Case
Specification
17.5mm*120mm
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
Production Capacity
500 Cases/Week

Product Description

50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
Characteristic

 

1. Tubes: made of strong, highly transparent medical grade polypropylene

2. Flat-top caps: made of medical grade polyethylene

3. Plug-seal screw on caps: made of medical grade polypropylene

4. 15ml and 50ml conical tubes available; large white writing area for easy marking

5. Double threaded design reduces cross-threading; caps are easily opened and closed

6. Flat-top caps can be written on

7. Gamma radiation sterilized, non-pyrogenic

8. Available in racked package (sterile) or bulk package (sterile & non-sterile)

9. RNase & DNase free

 

Specifications

1. Working temperature: stable from -20°C to 121°C (except flat-top cap)

2. 15ml and 50ml tubes can withstand centrifugation of 8,400 and 9,400 RCF

respectively

3. Sealing test: complies with The International Air Transport Association (IATA)

Safety Standards
 

 10-0501  50ml, Plug-seal Cap, PP Tube, Sterile, DNase & RNase Free, Conical Bottom, Rack Pack, 25 Tubes/Rack, 20 Racks/Case
 10-0502  50ml, Plug-seal Cap, PP Tube, Sterile, DNase & RNase Free, Conical Bottom, Bulk Pack, 25 Tubes/Bag, 20 Racks/Case
 10-9501  50ml, Flat-top Cap, PP Tube, Sterile, DNase & RNase Free, Conical Bottom, Rack Pack, 25 Tubes/Rack, 20 Racks/Case
 10-9502  50ml, Flat-top Cap, PP Tube, Sterile, DNase & RNase Free, Conical Bottom, Bulk Pack, 25 Tubes/Bag, 20 Racks/Case
50ml Centrifuge Tubes Can Withstand Centrifugation of 8, 400 and 9, 400 Rcf Respectively
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier