3ml pasteur pipet Sterilized Transfer Pipets with Gamma Sterile
Features
*Polyethylene pipettes will not shatter or break
*Good alternative to pasture pipettes and rubber bulbs
*Perfect products for quick, safe transfer of fluid
*Long flexible stem can be bent to draw liquid from
Narrow or small volume tubes into the bulb
*Uniform drop size
*Available with gamma irradiation sterilized or non-sterilized
*Integral, self-contained pipettes eliminate the problems of
Attaching rubber bulbs and suction devices or changing
Pipette tips
*Good thickness distribution guarantees suction force
Packaging
*Individually package in easy-open paper/plastic pouch is available
*Also available with bulk package in easy-open plastic bags
Pipet Design
*Available with 2 capacities of 1.0 and 3.0ml
*Molded graduations
*100% inert for accurate sampling
*Transparent wall permits easy viewing of pipette contents.
Cat#
|
Package
|
Length
|
Graduated to
|
Sterile
|
Unit
|
30-0135
|
Bulk
|
160.0mm
|
1ml
|
No
|
500/pack,10packs/case
|
30-0135A1
|
Individually
Wrapped
|
160.0mm
|
1ml
|
Yes
|
500/pack,10packs/case
|
|
|
|
|
|
|
30-0138
|
Bulk
|
160.0mm
|
3ml
|
No
|
500/pack,10packs/case
|
30-0138A1
|
Individually
Wrapped
|
160.0mm
|
3ml
|
Yes
|
500/pack,10packs/case
|
-
- What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
- What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.