Sterile Syringe Filterss Excellent Throughput, for Faster Filtration and More Process Volume 08-Ca3045r

Product Details
Outer Diameter: 30mm
Pore Size: 0.45um
Media Material: PES
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Sterile Syringe Filterss Excellent Throughput, for Faster Filtration and More Process Volume 08-Ca3045r
  • Sterile Syringe Filterss Excellent Throughput, for Faster Filtration and More Process Volume 08-Ca3045r
  • Sterile Syringe Filterss Excellent Throughput, for Faster Filtration and More Process Volume 08-Ca3045r
Find Similar Products

Basic Info.

Model NO.
08-CA3045R
Transport Package
4 Packs/Case
Specification
100 Pcs/Pack
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Product Description

Characteristic
 

1. Various available diameters (13, 25, 30mm): right size for the right volume or particulate load.

2. Available with PES membrane: provides >98.5% percent protein recovery.

3. Pre-sterilized: ready to use for sterile filtration and clarification of biological fluids.

4. Non-pyrogenic, low extractables and surfactant-free ensures purity of filtrate.

5. Extreme-low Protein Binding <1.5% (PES).

6. Excellent throughput, for faster filtration and more process volume.

 

Applications
 

1. Sterile filtration and clarification of biological fluids.

2. Tissue culture media preparation.

3. Protein and enzyme filtration.

4. Hybridization buffers.

5. Other aqueous solution.

Ordering Information

 

Cat # Description Unit
08-PES1322R Membrane: PES, pore size: 0.22μm, diameter:13mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 8 Packs/Case, Case of 800
08-PES2522R Membrane: PES, pore size: 0.22μm, diameter:25mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/Case, Case of 400
08-PES3022R Membrane: PES, pore size: 0.22μm, diameter:30mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/Case, Case of 400
08-PES3322S Membrane: PES, pore size: 0.22μm, diameter:33mm. Double luer lock.  Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-PES3345S Membrane: PES, pore size: 0.45μm, diameter:33mm. Double luer lock. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-PES3322M Membrane: PES, pore size: 0.22μm, diameter:33mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-PES3345M Membrane: PES, pore size: 0.45μm, diameter:33mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-CA3022R Membrane: CA, pore size: 0.22μm, diameter:30mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-CA3045R Membrane: CA, pore size: 0.45μm, diameter:30mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case, Case of 400
Sterile Syringe Filterss Excellent Throughput, for Faster Filtration and More Process Volume 08-Ca3045r1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier