• Disposable Virus Collection Tube and Transportation
  • Disposable Virus Collection Tube and Transportation
  • Disposable Virus Collection Tube and Transportation
  • Disposable Virus Collection Tube and Transportation
  • Disposable Virus Collection Tube and Transportation
  • Disposable Virus Collection Tube and Transportation

Disposable Virus Collection Tube and Transportation

After-sales Service: 5 Years
Warranty: 5 Years
Disposable: Disposable
Certification: CE, ISO, FDA
Reactant State: Liquid
Material: Rubber / Plastic
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
19-
Name
Disposable Virus Collection Tube and Transportatio
Application
Sample Collection and Detection
Medium
2ml or 3ml Medium
Collection Tubes
6ml or 10ml Sample Collection Tubes
Package
1 or 2 Swabs and Tubes Containing Medium
Inactivated Mediun
Nactivated Mediun Available
Non-Inactivated Mediun
Non-Inactivated Mediun Available
Transport Package
50 PCS/Box, 10 Boxes/Case Case of 500
Specification
CE, ISO, FDA
Trademark
BIOLOGIX
Origin
Changzhou, Jiangsu, China.
Production Capacity
3000 Cases/Month

Product Description


Disposable Virus Collection Tube and Transportation, Preservation Medium VTM PCR Sample Collection With Swab and Medium Virus Sample Collection
Disposable Virus Collection Tube and Transportation
Disposable Virus Collection Tube and Transportation
Disposable Virus Collection Tube and Transportation

Main component:
  1. Including: One Swab and one 12ml tube containing medium.
  2. Medium: 3ml Classic Medium
  3. Classic medium: HBSS, Antibiotics, BSA, Cryoprotectant, Biological Buffer, Phenol Red
 
Applications:

Applicable for the collection and transportation of clinical flu, avian flu, HFMD, measles and other virus samples as well as mycoplasma, urea plasma, chlamydia and other samples.
 

Storage Conditions And Validity:

12 months storage at 5-25ºC
 

Features:
  1. Multiple antibiotics are used in the solution to prevent bacterial and fungal contamination.
  2. BSA was added as protein stabilizer, protects virus samples and improves separation rate.
  3. The thickening and leakage prevention design ensured the samples non leakage, in accordance with WHO regulations and biosafety regulations.

Note:

Disposable Virus Collection Tube & Transportation, Preservation Medium is red, transparent, non-precipitating liquid. If the properties change, such as yellow, it is prohibited to use.

If long-distance transportation is needed, it is suggested to use cold chain (5-25 ºC) to ensure the best use of the medium.


Ordering Information:
Description Cat #   Pack Size

Disposable Virus Collection Tube & Transportation, Preservation Medium

19-1301-(Classic) 3ml/pc x 50 pcs/box, 10 boxs/case
19-1252-(Classic) 2ml/pc x 50 pcs/box, 10 boxs/case
Disposable Virus Collection Tube & Transportation, Preservation Medium 19-1302-(Inactivated ) 3ml/pc x 50 pcs/box, 10 boxs/case
19-1262-(Inactivated ) 2ml/pc x 50 pcs/box, 10 boxs/case
Disposable Virus Collection Tube and Transportation
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP