Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Reactant State: Solid
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
  • Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
  • Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
  • Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
  • Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
  • Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
Find Similar Products

Basic Info.

Model NO.
15-1040/15-1070/15-1100
Material
Rubber / Plastic
Size
40/70/100μm
Color
Purple/Orange/Green
Sterile
Yes
Package
Individual
Unit
1/Bag, 100 Bags/Case
Total
100/Case
Transport Package
100 /Case
Specification
1 /Bag, 100 Bags/Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Packaging & Delivery

Package Size
15.00cm * 10.00cm * 12.00cm
Package Gross Weight
2.300kg

Product Description

Laboratory Disposable Consumable 40/70/100μm Individually Wrapped Sterile Cell Strainers

Feature:

· Sterile Cell Strainer Laboratory Filters 40μm, 70μm, 100μm Cell Filter Strainer

· Made of sturdy polypropylene and strong nylon mesh

· Three different pore sizes available: 40/70/100μm, strainers are color-coded according to pore size for convenience

· Fits perfectly into Biologix 50ml Centrifuge Tubes

· Gamma radiation sterilized, non-pyrogenic

· Sterile, Individual package


Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers
Ordering Information
Cat # Size(μm) Color Unit Total
15-1040 40 Purple 1/Bag,100 Bags/Case 100 Pcs/Case
15-1070 70 Orange 1/Bag,100 Bags/Case 100 Pcs/Case
15-1100 100 Green 1/Bag,100 Bags/Case 100 Pcs/Case

 

Laboratory Disposable Consumable 40/70/100μ M Individually Wrapped Sterile Cell Strainers1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier