Polypropylene Pipet Tips autoclavable
Features:
-- Flexible tail vertebrae, compatible with major brands of pipettes
-- Extra-long design minimizes contamination during handling
-- Made of polypropylene, autoclavable
-- Available in 10μl, 200μl and 1000μl sizes, suitable for standard manual and electronic pipettes
-- 10μl and 200μl tips are graduated, 200μl tips have a beveled point design that reduces sample retention
Extended 1000μl tips facilitate pipetting from deep or narrow containers
-- RNase & DNase free, non-pyrogenic
-- Available in racked package (sterile) and bulk package (non-sterile)
-- RNase & DNase free
-- 10ul Tip are natural clear color
Cat # |
Volume |
Color |
Sterile |
Unit |
20-0010 |
10μl |
Natural |
NO |
1,000 Tips/Pack, 10 Packs/Case |
21-0010 |
10μl |
Natural |
YES |
96 Tips/Rack, 100 Racks/Case |
20-0200 |
200μl |
Yellow |
No |
1,000 Tips/Pack, 10 Packs/Case |
21-0200 |
200μl |
Yellow |
YES |
96 Tips/Rack, 100 Racks/Case |
20-1000 |
1000μl |
Blue |
NO |
1,000 Tips/Pack, 10 Packs/Case |
20-1250 |
1000μl Extended |
Natural |
NO |
1,000 Tips/Pack, 10 Packs/Case |
21-1000 |
1000μl |
Blue |
YES |
100 Tips/Rack, 60 Racks/Case |
21-1250 |
1000μl Extended |
Natural |
YES |
96 Tips/Pack, 60 Racks/Case |
20-1251 |
1000μl Extra-long |
Blue |
NO |
1,000 Tips/Bag, 10 Bags/Case |
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
At Biologix, we look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more, all in order to consistently ensure customer satisfaction. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Our facility is equipped with the latest instruments and technology from the most trusted manufacturers, ensuring that Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc.