25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Reactant State: Liquid
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
  • 25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
  • 25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
  • 25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
  • 25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
  • 25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
Find Similar Products

Basic Info.

Model NO.
07-8025 07-8075 07-8175 07-9025 07-9075 07-9175
Material
Rubber / Plastic
Sterile
Yes
Culture Area
25cm2 75cm2 125cm2
Working Volume
25ml 50ml 75ml
Surface Treatment
Yes
Cap Type
Filter Plug
Transport Package
5 Pieces/Pack, 40 Packs/Case
Specification
60ml 250 ml 650 ml
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3926909090
Production Capacity
200 Cases/Week

Product Description

 25 cm 75 cm 175 cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
 
25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
 
25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
Characteristic

1.Made of high quality medical grade polystyrene

2.Available flask sizes include surface areas of 25 cm2, 75 cm2, or 175 cm2

3.Plug cap and filter cap options available for all flask sizes

4.Plug caps completely isolate the culture from the outside environment

5.Filter caps prevent cross-contamination while meeting the requirements for gas exchange

6.Short, wide, angled neck design for easy access

7.Gamma radiation sterilized

8.Non-pyrogenic, non-cyotoxic

9.DNase & RNase free, human DNA free

Ordering Information

    Cat # Cap Type

    Culture

     Area

    Working 

    Volume

    Total 

    Volume

    Surface 

    Treatment

    Sterile Unit
    07-8025 Filter 25cm2 7ml 60ml YES YES 5 Pieces/Pack, 40 Packs/Case
    07-8075 Filter 75cm2 25ml 250ml YES YES 5 Pieces/Pack, 20 Packs/Case
    07-8175 Filter 175cm2 50ml 650ml YES YES 5 Pieces/Pack, 8 Packs/Case
    07-9025 Plug 25cm2 7ml 60ml YES YES 5 Pieces/Pack, 40 Packs/Case
    07-9075 Plug 75cm2 25ml 250ml YES YES 5 Pieces/Pack, 20 Packs/Case
    07-9175 Plug 175cm2 50ml 650ml YES YES 5 Pieces/Pack, 8 Packs/Case

    25 Cm 75 Cm 175 Cm Tissue Culturetreated Disposable Laboratory Plastic Sterile Cell Culture Flask
    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier