Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker

Product Details
Certification: CE, ISO, FDA
Tilt Angle:
Max.Load Capacity(with Platform): 2kg
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker
  • Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker
  • Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker
  • Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker
  • Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker
  • Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker
Find Similar Products

Basic Info.

Model NO.
01-631XA
Motor Type
DC Motor
Speed Range
10-80rpm
Time Settings Range
1min-99h59min
Dimension[W×d×h]
294×348×123mm
Trademark
Biologix
Origin
Changzhou, Jiangsu, China

Product Description

Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker

Feature:
· Intelligent Transference Decolorizing Shaker
· Rocking motion angle 7°
· Speed range 10-70rpm, 2kg and speed range 10-80rpm
· Double LCDs/LEDs for independent display of time and speed
· Continuous or timer operation mode
· Electronic time switching clock: lmin-99h59min
· Wide range of platforms for use with a variety of vessels
· Simple appearance, save operating space

Applications

Designed for time-dependent and low rpmsensitive shaking applications such as ELISAwashes, enzyme immunoassays, proteinsynthesis, hybridization staining/destaininggels, immune precipitation and Western blots, cell culture, pharmaceutical profiling, etc.
 

Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker

Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker
Ordering Information
Specifications 01-631XA
Tilt angle
Max.load capacity(with platform) 2kg
Motor type DC motor
Input power 20W
Output power 16W
Speed range 10-80rpm
Speed display LED
Timer display LED
Time settings range 1min-99h59min
Voltage, Frequency 100-240V,50/60Hz
Power 20W
Weight 3.1kg
Permissible ambient
temperature and humidity
5-40ºC,80%RH
Dimension[W×D×H] 294×348×123mm
Protection class IP21

 

Lab Equipment Continuous or Timer Operation Mode Intelligent Transference Decolorizing Shaker1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier